The only agent that thinks for itself

Autonomous Monitoring with self-learning AI built-in, operating independently across your entire stack.

Unlimited Metrics & Logs
Machine learning & MCP
5% CPU, 150MB RAM
3GB disk, >1 year retention
800+ integrations, zero config
Dashboards, alerts out of the box
> Discover Netdata Agents

Centralized metrics streaming and storage

Aggregate metrics from multiple agents into centralized Parent nodes for unified monitoring across your infrastructure.

Stream from unlimited agents
Long-term data retention
High availability clustering
Data replication & backup
Scalable architecture
Enterprise-grade security
> Learn about Parents

Fully managed cloud platform

Access your monitoring data from anywhere with our SaaS platform. No infrastructure to manage, automatic updates, and global availability.

Zero infrastructure management
99.9% uptime SLA
Global data centers
Automatic updates & patches
Enterprise SSO & RBAC
SOC2 & ISO certified
> Explore Netdata Cloud

Deploy Netdata Cloud in your infrastructure

Run the full Netdata Cloud platform on-premises for complete data sovereignty and compliance with your security policies.

Complete data sovereignty
Air-gapped deployment
Custom compliance controls
Private network integration
Dedicated support team
Kubernetes & Docker support
> Learn about Cloud On-Premises

Powerful, intuitive monitoring interface

Modern, responsive UI built for real-time troubleshooting with customizable dashboards and advanced visualization capabilities.

Real-time chart updates
Customizable dashboards
Dark & light themes
Advanced filtering & search
Responsive on all devices
Collaboration features
> Explore Netdata UI

Monitor on the go

Native iOS and Android apps bring full monitoring capabilities to your mobile device with real-time alerts and notifications.

iOS & Android apps
Push notifications
Touch-optimized interface
Offline data access
Biometric authentication
Widget support
> Download apps

The future of infrastructure observability

See our strategic direction across AI-native observability, full-stack signals, operational intelligence, and enterprise platform maturity.

AI-native observability
Full-stack signal coverage
Operational intelligence
Enterprise platform maturity
Agent releases every 6 weeks
Cloud continuous delivery
> Explore Product Roadmap

Best energy efficiency

True real-time per-second

100% automated zero config

Centralized observability

Multi-year retention

High availability built-in

Zero maintenance

Always up-to-date

Enterprise security

Complete data control

Air-gap ready

Compliance certified

Millisecond responsiveness

Infinite zoom & pan

Works on any device

Native performance

Instant alerts

Monitor anywhere

AI-native observability

Continuous delivery

Open source foundation

80% Faster Incident Resolution

AI-powered troubleshooting from detection, to root cause and blast radius identification, to reporting.

True Real-Time and Simple, even at Scale

Linearly and infinitely scalable full-stack observability, that can be deployed even mid-crisis.

90% Cost Reduction, Full Fidelity

Instead of centralizing the data, Netdata distributes the code, eliminating pipelines and complexity.

See and Map Your Entire Network

Live topology, flow analytics, and SNMP device and trap monitoring — unified with your full-stack observability.

Control Without Surrender

SOC 2 Type 2 certified with every metric kept on your infrastructure.

Integrations

800+ collectors and notification channels, auto-discovered and ready out of the box.

800+ data collectors
Auto-discovery & zero config
Cloud, infra, app protocols
Notifications out of the box
> Explore integrations
Real Results
46% Cost Reduction

Reduced monitoring costs by 46% while cutting staff overhead by 67%.

— Leonardo Antunez, Codyas

Zero Pipeline

No data shipping. No central storage costs. Query at the edge.

From Our Users
"Out-of-the-Box"

So many out-of-the-box features! I mostly don't have to develop anything.

— Simon Beginn, LANCOM Systems

No Query Language

Point-and-click troubleshooting. No PromQL, no LogQL, no learning curve.

Enterprise Ready
67% Less Staff, 46% Cost Cut

Enterprise efficiency without enterprise complexity—real ROI from day one.

— Leonardo Antunez, Codyas

SOC 2 Type 2 Certified

Zero data egress. Only metadata reaches the cloud. Your metrics stay on your infrastructure.

Full Coverage
800+ Collectors

Auto-discovered and configured. No manual setup required.

Any Notification Channel

Slack, PagerDuty, Teams, email, webhooks—all built-in.

Built for the People Who Get Paged

Because 3am alerts deserve instant answers, not hour-long hunts.

Every Industry Has Rules. We Master Them.

See how healthcare, finance, and government teams cut monitoring costs 90% while staying audit-ready.

Monitor Any Technology. Configure Nothing.

Install the agent. It already knows your stack.
From Our Users
"A Rare Unicorn"

Netdata gives more than you invest in it. A rare unicorn that obeys the Pareto rule.

— Eduard Porquet Mateu, TMB Barcelona

99% Downtime Reduction

Reduced website downtime by 99% and cloud bill by 30% using Netdata alerts.

— Falkland Islands Government

Real Savings
30% Cloud Cost Reduction

Optimized resource allocation based on Netdata alerts cut cloud spending by 30%.

— Falkland Islands Government

46% Cost Cut

Reduced monitoring staff by 67% while cutting operational costs by 46%.

— Codyas

Real Coverage
"Plugin for Everything"

Netdata has agent capacity or a plugin for everything, including Windows and Kubernetes.

— Eduard Porquet Mateu, TMB Barcelona

"Out-of-the-Box"

So many out-of-the-box features! I mostly don't have to develop anything.

— Simon Beginn, LANCOM Systems

Real Speed
Troubleshooting in 30 Seconds

From 2-3 minutes to 30 seconds—instant visibility into any node issue.

— Matthew Artist, Nodecraft

20% Downtime Reduction

20% less downtime and 40% budget optimization from out-of-the-box monitoring.

— Simon Beginn, LANCOM Systems

Pay per Node. Unlimited Everything Else.

One price per node. Unlimited metrics, logs, users, and retention. No per-GB surprises.

Free tier—forever
No metric limits or caps
Retention you control
Cancel anytime
> See pricing plans

What's Your Monitoring Really Costing You?

Most teams overpay by 40-60%. Let's find out why.

Expose hidden metric charges
Calculate tool consolidation
Customers report 30-67% savings
Results in under 60 seconds
> See what you're really paying

Your Infrastructure Is Unique. Let's Talk.

Because monitoring 10 nodes is different from monitoring 10,000.

On-prem & air-gapped deployment
Volume pricing & agreements
Architecture review for your scale
Compliance & security support
> Start a conversation

Monitoring That Sells Itself

Deploy in minutes. Impress clients in hours. Earn recurring revenue for years.

30-second live demos close deals
Zero config = zero support burden
Competitive margins & deal protection
Response in 48 hours
> Apply to partner

Per-Second Metrics at Homelab Prices

Same engine, same dashboards, same ML. Just priced for tinkerers.

Community: Free forever · 5 nodes · non-commercial
Homelab: $90/yr · unlimited nodes · fair usage
> Get the Homelab Plan

$1,000 Per Referral. Unlimited Referrals.

Your colleagues get 10% off. You get 10% commission. Everyone wins.

10% of subscriptions, up to $1,000 each
Track earnings inside Netdata Cloud
PayPal/Venmo payouts in 3-4 weeks
No caps, no complexity
> Get your referral link
Cost Proof
40% Budget Optimization

"Netdata's significant positive impact" — LANCOM Systems

Calculate Your Savings

Compare vs Datadog, Grafana, Dynatrace

Savings Proof
46% Cost Reduction

"Cut costs by 46%, staff by 67%" — Codyas

30% Cloud Bill Savings

"Reduced cloud bill by 30%" — Falkland Islands Gov

Enterprise Proof
"Better Than Combined Alternatives"

"Better observability with Netdata than combining other tools." — TMB Barcelona

Real Engineers, <24h Response

DPA, SLAs, on-prem, volume pricing

Why Partners Win
Demo Live Infrastructure

One command, 30 seconds, real data—no sandbox needed

Zero Tickets, High Margins

Auto-config + per-node pricing = predictable profit

Homelab Ready
Free Video Course

8-episode Netdata tutorial by LearnLinux.tv

76k+ GitHub Stars

3rd most starred monitoring project

Worth Recommending
Product That Delivers

Customers report 40-67% cost cuts, 99% downtime reduction

Zero Risk to Your Rep

Free tier lets them try before they buy

AI Support Assistant, Available 24/7

Nedi has access to all official documentation, source code, and resources. Ask any question about Netdata—responds in your language.

Deployment & configuration
Troubleshooting & sizing
Alerts & notifications
Evidence-based answers
> Ask Nedi now

Never Fight Fires Alone

Docs, community, and expert help—pick your path to resolution.

Learn.netdata.cloud docs
Discord, Forums, GitHub
Premium support available
> Get answers now

60 Seconds to First Dashboard

One command to install. Zero config. 850+ integrations documented.

Linux, Windows, K8s, Docker
Auto-discovers your stack
> Read our documentation

76,000+ Engineers Strong

615+ contributors. 1.5M daily downloads. One mission: simplify observability.

Per-Second. 90% Cheaper. Data Stays Home.

Side-by-side comparisons: costs, real-time granularity, and data sovereignty for every major tool.

See why teams switch from Datadog, Prometheus, Grafana, and more.

> Browse all comparisons
Edge-Native Observability, Born Open Source
Per-second visibility, ML on every metric, and data that never leaves your infrastructure.
Founded in 2016
615+ contributors worldwide
Remote-first, engineering-driven
Open source first
> Read our story
Promises We Publish—and Prove
12 principles backed by open code, independent validation, and measurable outcomes.
Open source, peer-reviewed
Zero config, instant value
Data sovereignty by design
Aligned pricing, no surprises
> See all 12 principles
Edge-Native, AI-Ready, 100% Open
76k+ stars. Full ML, AI, and automation—GPLv3+, not premium add-ons.
76,000+ GitHub stars
GPLv3+ licensed forever
ML on every metric, included
Zero vendor lock-in
> Explore our open source
Build Real-Time Observability for the World
Remote-first team shipping per-second monitoring with ML on every metric.
Remote-first, fully distributed
Open source (76k+ stars)
Challenging technical problems
Your code on millions of systems
> See open roles
Meet the Team Behind Netdata
Conferences, meetups, and tradeshows where you can see Netdata in action and talk to the engineers who build it.
Live demos and deep dives
Book 1-on-1 meetings
Talks and panel sessions
Event recaps and photos
> See all events
Talk to a Netdata Human in <24 Hours
Sales, partnerships, press, or professional services—real engineers, fast answers.
Discuss your observability needs
Pricing and volume discounts
Partnership opportunities
Media and press inquiries
> Book a conversation
Your Data. Your Rules.
On-prem data, cloud control plane, transparent terms.
Trust & Scale
76,000+ GitHub Stars

One of the most popular open-source monitoring projects

SOC 2 Type 2 Certified

Enterprise-grade security and compliance

Data Sovereignty

Your metrics stay on your infrastructure

Validated
University of Amsterdam

"Most energy-efficient monitoring solution" — ICSOC 2023, peer-reviewed

ADASTEC (Autonomous Driving)

"Doesn't miss alerts—mission-critical trust for safety software"

Community Stats
615+ Contributors

Global community improving monitoring for everyone

1.5M+ Downloads/Day

Trusted by teams worldwide

GPLv3+ Licensed

Free forever, fully open source agent

Why Join?
Remote-First

Work from anywhere, async-friendly culture

Impact at Scale

Your work helps millions of systems

$ guides / smartctl-disk-monitoring / smartctl-spin-up-time-rising ▌

Operations Guides

Spin_Up_Time climbing: bearing wear and lubricant degradation

Spin_Up_Time (SMART attribute ID 3) measures how long the spindle motor takes to bring the platters from zero to rated RPM. The raw value is vendor-specific and noisy. A rising Spin_Up_Time alone is ambiguous; it becomes actionable only when you correlate it with Spin_Retry_Count (ID 10), drive temperature, and the scope of the problem across the chassis.

This attribute applies only to mechanical HDDs. SSDs have no spindle motor and report Spin_Up_Time as zero or a synthetic placeholder.

What this means

Spin_Up_Time is ATA SMART attribute ID 3. The raw value nominally represents milliseconds to reach operational RPM, but the encoding is vendor-specific. Some manufacturers store a vendor-encoded bitfield rather than a simple millisecond count, so the raw value may not be directly comparable across drive models or even firmware revisions. The normalized VALUE column is more reliable for trend analysis. Most manufacturers use 100 or 200 as the healthy baseline, with lower values indicating degradation.

A climbing Spin_Up_Time means the spindle motor is working harder to reach rated RPM. The mechanical causes are progressive: bearing wear increases rotational friction, lubricant viscosity changes with age, and motor driver circuitry can degrade. Each forces the motor to draw more current and take longer to stabilize.

Environmental and infrastructure factors confound the reading. Cold lubricant thickens, slowing spin-up even on a healthy drive. A sagging 12V rail cannot deliver sufficient inrush current, producing the same symptom as bearing wear. Rule out temperature and power delivery before concluding the motor is failing.

The critical corroboration is Spin_Retry_Count (attribute ID 10). If Spin_Up_Time is rising and Spin_Retry_Count is also non-zero or increasing, the motor system is failing. This pairing is the strongest mechanical failure signal in the SMART attribute set.

flowchart TD
    A["Spin_Up_Time rising"] --> B{"Spin_Retry_Count > 0?"}
    B -- Yes --> C["Motor system failing"]
    C --> D["Plan urgent replacement"]
    B -- No --> E{"Multiple drives affected?"}
    E -- Yes --> F["Power supply or backplane issue"]
    E -- No --> G{"Cold start or low ambient temp?"}
    G -- Yes --> H["Likely temperature confounding"]
    G -- No --> I["Single-drive bearing wear"]
    I --> J["Monitor trend vs baseline"]

Common causes

CauseWhat it looks likeFirst thing to check
Bearing wearGradual creep in normalized value over weeks or months, single drive onlyCompare current normalized value against deployment baseline
Lubricant degradationNormalized value trending down, possibly correlated with sustained high operating temperatureCheck temperature history for sustained operation above 50C
Cold ambient temperatureSudden jump after cold start or in cold facility, recovers when warmCorrelate spin-up readings with ambient temperature at spin-up time
Power delivery sagMultiple drives showing spin retries or elevated spin-up times simultaneouslyCheck 12V rail voltage and staggered spin-up configuration
Sparse data misinterpretationApparent change on a drive that rarely spins down or has very few power cyclesCheck Power Cycle Count before trusting the trend

Quick checks

# Full SMART attribute snapshot (spin-up, retries, temp, power-on hours, cycles)
smartctl -A /dev/sdX

# Isolate spin-up signals for scripting
smartctl -A /dev/sdX | grep -iE "Spin_Up_Time|Spin_Retry|Power_Cycle|Power_On|Temperature"

# Overall health assessment
smartctl -H /dev/sdX

# Confirm the drive is mechanical (SSDs report meaningless Spin_Up_Time)
smartctl -i /dev/sdX | grep -i "Rotation Rate"

How to diagnose it

  1. Confirm the drive is mechanical. Check smartctl -i /dev/sdX for “Rotation Rate.” If it shows “Solid State Device,” this attribute is irrelevant.

  2. Establish the baseline. If you captured a SMART snapshot at deployment, compare the current normalized VALUE against it. The raw value alone is not reliable across vendors. It is common for the normalized value to drop from 100 to 90 after just a few power cycles on a healthy drive. This is expected, not damage. The concern is a continuing downward trend or a sudden jump greater than 2x from the established baseline.

  3. Check for temperature confounding. Cold lubricant thickens and slows spin-up. If the drive is in a cold facility, an unheated rack, or was just powered on after a cold soak, a temporary increase is expected. Normalize for temperature by comparing readings taken at similar ambient conditions. A single spin retry on a very cold drive (below roughly 10C) may be acceptable. Conversely, sustained operation above 50C accelerates lubricant breakdown, so a long-term upward temperature trend can cause a real, permanent increase in spin-up time.

  4. Check Spin_Retry_Count. This is the decisive corroboration. If the raw value is non-zero and increasing alongside rising Spin_Up_Time, the motor is failing to reach operational speed on the first attempt. This pairing indicates mechanical motor system failure, not environmental confounding. Any non-zero Spin_Retry_Count on an enterprise drive is abnormal.

  5. Scope the problem across drives. If multiple drives in the same chassis show spin retries or elevated spin-up times simultaneously, the root cause is power delivery, not individual drive bearings. Check the 12V rail, PSU health, and whether staggered spin-up is configured. If only one drive shows the symptom, it is that drive’s motor.

  6. Check power cycle frequency. Drives that never spin down (typical servers with no power management) accumulate very few spin-up data points. A drive with a low power cycle count has sparse data for this attribute, making trend analysis unreliable. The signal is most informative for drives that actually transition between standby and active states.

  7. Factor in drive age. Cross-reference Power-On Hours. Drives above roughly 50,000 hours (about 5.7 years) have a higher baseline failure probability regardless of SMART status. Bearing wear and lubricant degradation are age-related, so a climbing Spin_Up_Time on an older drive is more likely real mechanical degradation than a transient anomaly.

Metrics and signals to monitor

SignalWhy it mattersWarning sign
Spin_Up_Time normalized VALUE (ID 3)Tracks spindle motor health over timeSustained downward trend or sudden jump greater than 2x from baseline
Spin_Retry_Count (ID 10)Decisive corroboration of motor failureAny non-zero value on an enterprise drive
Drive Temperature (ID 194)Cold confounds spin-up; heat degrades lubricantCold: below 10C at spin-up. Hot: sustained above 50C
Power Cycle Count (ID 12)Context for spin-up data densityLow count means sparse data; high count increases motor wear
Power-On Hours (ID 9)Normalizes wear against drive ageAbove 50,000 hours increases baseline failure probability
Cross-drive spin symptomsDistinguishes power problem from individual drive failureMore than one drive in the same chassis showing spin retries

Fixes

Bearing wear or lubricant degradation

There is no software fix for mechanical bearing wear. Once the spindle bearings are degraded or the lubricant has broken down, the drive is on a failure trajectory. Plan replacement.

If Spin_Retry_Count is non-zero, treat this as urgent. A drive that retries spin-up may not come back after the next power cycle. Schedule replacement before the next planned maintenance window, and avoid unnecessary power cycles in the meantime. The timeline from first symptom to complete failure is unpredictable: a drive with slowly increasing spin-up time may run for months, or it may fail to spin up after the next power-off.

Power delivery issues

If multiple drives show spin retries or elevated spin-up times simultaneously, the fix is at the infrastructure layer:

  • Verify the PSU can deliver sufficient inrush current for all drives. Enterprise drives draw significantly more current during spin-up than during steady-state operation.
  • Enable staggered spin-up (Power Up In Standby, or controller-level staggered start) so drives do not all surge simultaneously after a chassis power event.
  • Check the 12V rail voltage under load. A sagging rail produces symptoms identical to bearing wear.
  • Inspect backplane power delivery connectors for corrosion, looseness, or damage.

Cold environment confounding

If the increase correlates with low ambient temperature, no drive action is needed. The drive will return to baseline spin-up time once it warms up. If drives operate in a permanently cold facility, expect consistently higher spin-up times as a baseline characteristic, not a degradation signal. Adjust monitoring thresholds accordingly so the temperature-normalized baseline does not generate false alerts.

Prevention

  • Baseline every drive at deployment. Capture a full smartctl -a snapshot. Without a baseline, you cannot distinguish a normal normalized value drop after a few power cycles from a real degradation trend.
  • Normalize for temperature. Track spin-up time alongside ambient temperature. Alert on deviations from the temperature-normalized baseline, not on absolute values.
  • Enable staggered spin-up. Prevents power delivery sag from producing false spin-up symptoms on every chassis power cycle.
  • Monitor Spin_Retry_Count alongside Spin_Up_Time. Either signal alone is ambiguous. Together they are the strongest mechanical failure indicator in the SMART attribute set.
  • Keep drives in their thermal sweet spot. For HDDs, the target range is roughly 25 to 45C. Cold thickens lubricant and confounds spin-up readings; sustained heat above 50C accelerates lubricant breakdown.
  • Avoid unnecessary power cycles. Every spin-up stresses the motor and consumes lubricant life. Drives designed for continuous operation accumulate the most reliable trend data when they run uninterrupted.

How Netdata helps

Netdata’s smartctl collector captures Spin_Up_Time (ID 3) and Spin_Retry_Count (ID 10) alongside drive temperature and power cycle count at per-second resolution. The diagnostic value comes from correlating these signals:

  • Track the normalized VALUE trend per drive to detect gradual bearing wear before it escalates to Spin_Retry_Count growth.
  • Correlate Spin_Up_Time changes with temperature readings to separate cold-environment confounding from real mechanical degradation.
  • Detect multi-drive patterns: if several drives in the same chassis show spin-up changes simultaneously, the dashboard makes the infrastructure-level pattern visible immediately, pointing to power delivery rather than individual drive failure.
  • ML anomaly detection flags sudden jumps from baseline that warrant investigation, even when absolute values remain within nominal ranges.
  • Alert on Spin_Retry_Count non-zero values as a high-specificity mechanical failure signal, independent of the noisier Spin_Up_Time trend.