Plugin: go.d.plugin Module: snmp
Monitor Servertech Pdu3 (pdu) with Netdata over SNMP. Netdata recognizes the device automatically by its sysObjectID (recognized across 1 device identifiers) and collects the metrics this profile declares — on top of the generic SNMP baseline — with no manual OID configuration.
Netdata’s SNMP collector matches the device to the servertech-pdu3.yaml profile via sysObjectID/sysDescr, then polls the OIDs it declares.
This integration is supported on all platforms.
This integration supports multiple instances configured side-by-side.
Auto-detected as Servertech Pdu3 via sysObjectID/sysDescr.
The default configuration for this integration does not impose any limits.
The default configuration for this integration is not expected to impose a significant performance impact on the system.
You can configure the snmp collector in two ways:
| Method | Best for | How to |
|---|---|---|
| UI | Fast setup without editing files | Go to Nodes → Configure this node → Collectors → Jobs, search for snmp, then click + to add a job. |
| File | If you prefer configuring via file, or need to automate deployments (e.g., with Ansible) | Edit go.d/snmp.conf and add a job. |
Important
UI configuration requires paid Netdata Cloud plan.
SNMP must be enabled on the device and reachable from the Netdata Agent acting as the site’s SNMP hub.
Configure the SNMP collector with the device hostname and SNMP credentials. See the SNMP collector reference for all options.
Configure the snmp collector from the Netdata web interface:
The configuration file name for this integration is go.d/snmp.conf.
The file format is YAML. Generally, the structure is:
update_every: 1
autodetection_retry: 0
jobs:
- name: some_name1
- name: some_name2
You can edit the configuration file using the edit-config script from the
Netdata config directory.
cd /etc/netdata 2>/dev/null || cd /opt/netdata/etc/netdata
sudo ./edit-config go.d/snmp.conf
There are no configuration examples.
On top of the generic SNMP baseline (the Generic SNMP Device integration — interfaces, system, IP/TCP/UDP, host resources), this Servertech Pdu3 profile adds the metrics below. Each is collected only where the device exposes the matching OID — inclusion means the profile requests it; availability depends on the device model and software.
33 metrics in 9 groups; each row is a chart context usable in alerts.
| Group | Metrics |
|---|---|
| Hardware / Infeed | 2 |
| Hardware / Outlet | 3 |
| Hardware / Sensor | 6 |
| Hardware / Tower | 1 |
| PowerFlow / Infeed | 10 |
| PowerFlow / System | 1 |
| PowerFlow / Tower | 8 |
| System / Configuration | 1 |
| System / Uptime | 1 |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_infeedLoadStatus | {status} | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed load status |
snmp.device_prof_servertech_sentry3_infeedStatus | {status} | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed operational status |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_outletControlState | {status} | per servertech_sentry3_outlet_id, servertech_sentry3_outlet_name | Outlet control state |
snmp.device_prof_servertech_sentry3_outletStatus | {status} | per servertech_sentry3_outlet_id, servertech_sentry3_outlet_name | Outlet operational status |
snmp.device_prof_servertech_sentry3_outletWakeupState | {status} | per servertech_sentry3_outlet_id, servertech_sentry3_outlet_name | Outlet wakeup state configuration |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_envMonStatus | {status} | per servertech_sentry3_env_mon_id, servertech_sentry3_env_mon_name | Environmental monitor status |
snmp.device_prof_servertech_sentry3_tempHumidSensorHumidStatus | {status} | per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_name | Humidity sensor status |
snmp.device_prof_servertech_sentry3_tempHumidSensorHumidValue | % | per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_name | Humidity value from sensor |
snmp.device_prof_servertech_sentry3_tempHumidSensorStatus | {status} | per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_name | Temperature/humidity sensor communication status |
snmp.device_prof_servertech_sentry3_tempHumidSensorTempStatus | {status} | per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_name | Temperature sensor status |
snmp.device_prof_servertech_sentry3_tempHumidSensorTempValue | Cel | per servertech_sentry3_temp_humid_sensor_id, servertech_sentry3_temp_humid_sensor_name | Temperature value from sensor |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_towerStatus | {status} | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower operational status |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_infeedCapacity | VA | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed capacity |
snmp.device_prof_servertech_sentry3_infeedCapacityUsed | VA | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Used infeed capacity |
snmp.device_prof_servertech_sentry3_infeedEnergy | Wh | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed energy consumption |
snmp.device_prof_servertech_sentry3_infeedLoadValue | W | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed load value |
snmp.device_prof_servertech_sentry3_infeedOutletCount | {outlet} | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Number of outlets on infeed |
snmp.device_prof_servertech_sentry3_infeedPhaseCurrent | A | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed phase current |
snmp.device_prof_servertech_sentry3_infeedPhaseVoltage | V | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed phase voltage |
snmp.device_prof_servertech_sentry3_infeedPower | W | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed power |
snmp.device_prof_servertech_sentry3_infeedReactance | {status} | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed reactance type |
snmp.device_prof_servertech_sentry3_infeedVoltage | V | per servertech_sentry3_infeed_id, servertech_sentry3_infeed_name | Infeed voltage |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_systemTotalPower | W | device | Total power consumption of the system |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_towerActivePower | W | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower active power |
snmp.device_prof_servertech_sentry3_towerApparentPower | VA | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower apparent power |
snmp.device_prof_servertech_sentry3_towerEnergy | Wh | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower energy consumption |
snmp.device_prof_servertech_sentry3_towerInfeedCount | {infeed} | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Number of tower infeeds |
snmp.device_prof_servertech_sentry3_towerLineFrequency | Hz | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower line frequency |
snmp.device_prof_servertech_sentry3_towerPowerFactor | % | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower power factor |
snmp.device_prof_servertech_sentry3_towerVACapacity | VA | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Tower VA capacity |
snmp.device_prof_servertech_sentry3_towerVACapacityUsed | VA | per servertech_sentry3_tower_id, servertech_sentry3_tower_name | Used tower VA capacity |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_servertech_sentry3_systemConfigModifiedCount | {modification} | device | Count of system configuration modifications |
| Metric (chart context) | Unit | Scope | Description |
|---|---|---|---|
snmp.device_prof_systemUptime | s | device | Time since the system was last rebooted or powered on. |
There are no alerts configured by default for this integration.